The
control thermostat is positioned away from the elements
so as to sense the incoming water temperature and control
the pool to within 1°C.
The safety thermostat measures the temperature of the water as it leaves the
heater, providing perfect safety for the bathers. A temperature rise within
the heater, due to poor water flow conditions, is rapidly sensed by both the
control and the safety thermostat.
The
unique cup-shaped base design ensures that the heated part
of the element is always kept beneath the water, even if
the flow from the pump fails. Flow failure simply allows
the water in the cup to warm up and switch the heater off
instantly using the normal temperature controls.
All heaters 15kW and above have circuit breakers as well as the working contractor,
which are switched off by excess temperature.
 |
A considerable amount of water evaporates from the surface
of a heated swimming pool or spa pool.
If the pool is indoors, all this evaporated water is effectively
trapped within the pool room in the form of airborne humidity.
As the evaporation from the pool continues, the amount
of water with the pool room air quickly increases until
the point when the air can hold on more water.
Surface condensation will then occur on the windows, walls
and ceiling etc and condensation can also actually occur
within the structure of the pool room building.
This can soon lead to extensive mould growth, rapid deterioration
of the décor and possible eventual structural problems.
Effective air heating is also important within a pool room
as the quantity of water which evaporates from the pool
surface will be much increased if the air is not able to
be maintained at a high enough temperature.
With the option of built-in heating coils for air and pool
water, the Orion system provides an ideal solution to condensation
and temperature control. |
The Orion is designed and constructed to the highest
possible standard and all components have been especially
selected for use within corrosive swimming pool environments.
For maximum durability and strength, all exterior panels
are formed from galvanized steel, with a tough PVC coating
to prevent corrosion.
The refrigeration system is filled with zero ozone depletion
refrigerant and is completely hermetically sealed to guard
against leakage. |
 |
|